BICSI IN101_V7 (BICSI Installer 1) Exam is a certification examination that is designed for individuals who are interested in becoming a BICSI-certified installer. IN101_V7 exam is conducted by BICSI, which is a professional association that focuses on the advancement of the information and communications technology (ICT) industry. BICSI Installer 1 Exam certification demonstrates an individual's knowledge and skills in the installation, termination, and testing of copper and fiber optic cabling systems.
BICSI IN101_V7 exam is open to anyone who has completed the BICSI Installer 1 training course. IN101_V7 course is designed for individuals who are new to the cabling infrastructure industry or who have limited experience. IN101_V7 exam is also suitable for individuals who are looking to upgrade their skills or who are interested in pursuing a career in the cabling infrastructure field.
NEW QUESTION # 12
Which of the following fire ratings refers to the time period that the unexposed surface of a firestop assembly does not exceed 180 degrees C (325 degrees F) above its initial temperature?
- A. FT rating
- B. FH rating
- C. S rating
- D. E rating
Answer: A
NEW QUESTION # 13
What is the minimum inside bend radius for balanced twisted pair (4 pair) cable?
- A. 25 mm (1")
- B. 50 mm (2")
- C. 15 times the outside cable diameter
- D. 4 times the outside cable diameter
Answer: D
NEW QUESTION # 14
Which of the following topologies is the recommended topology for distribution systems in campus environments?
- A. Ring
- B. Star
- C. Hierarchical Star
- D. Tree
Answer: C
NEW QUESTION # 15
What is the minimum number of consolidation points that should serve an open office furniture cluster?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 16
Which of the following terms describes the unwanted signal coupling from a disturbing pair of a 4-pair cable channel to a disturbed pair of another 4-pair channel?
- A. NEXT - Near end crosstalk
- B. AXT - alien crosstalk
- C. ACRF - attenuation to crosstalk ratio far end
Answer: B
NEW QUESTION # 17
Which of the following markings is used for non-conductive optical fiber general-purpose cables?
- A. OFNG
- B. OFCR
- C. OFNP
- D. OFCP
Answer: A
NEW QUESTION # 18
How much sheath of the cable needs to be removed in order to properly terminate an 8P8C?
- A. 12.7mm (0.5")
- B. 38 mm (1.5")
- C. 25mm (1")
- D. 6.3mm (0.25")
Answer: A
NEW QUESTION # 19
Which of the following are typically used to support cables between a cable tray and work area outlets?
- A. Pipe hanger
- B. J-Hook
- C. Trapeze
- D. Innerduct
Answer: B
NEW QUESTION # 20
If you are working on a catwalk, you are required to wear _____?
- A. Safety belt
- B. Full body harness and two lanyards
- C. Nothing, your fine on the catwalk
Answer: B
NEW QUESTION # 21
What grade of plywood is recommended for use with ICT systems?
- A. A/D
- B. B/C
- C. C/D
- D. A/C
Answer: D
NEW QUESTION # 22
A radio station transmits an omnidirectional signal that is received by multiple radios. What type of transmission method is used in this example?
- A. Half-duplex
- B. Full-duplex
- C. Simplex
Answer: C
NEW QUESTION # 23
Which is a keyed, contact, moderate loss connector in present use today that is pull & wiggle-proof?
- A. SMA 906
- B. Opti-Jack
- C. Straight Tip (ST)
- D. Subscriber Connector (SC)
Answer: C
NEW QUESTION # 24
Which of the following types of cable produces very little smoke when burned?
- A. LSZH
- B. CMUC
- C. CMG
- D. CM
Answer: A
NEW QUESTION # 25
What is the characteristic impedance of Series-6 coaxial cable?
- A. 100 ohms
- B. 75 ohms
- C. 50 ohms
- D. 25 ohms
Answer: B
NEW QUESTION # 26
Which of the following makes the biggest impression on a customer when you are communicating via email?
- A. Tone of voice
- B. Body language
- C. Choice of words
Answer: C
NEW QUESTION # 27
Which tool is required to pull backbone cable of significant weight?
- A. Pull string
- B. Tugger
- C. Pulling eye
- D. Furcating harness
Answer: B
NEW QUESTION # 28
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______?
- A. 15 m (50')
- B. 10 m (33')
- C. 30 m (100')
- D. 5 m (16.5')
Answer: B
NEW QUESTION # 29
Which of the following refers to a set of rules issued by a governmental body at the state level within the US?
- A. Guidelines
- B. Applications
- C. Regulations
- D. Best Practices
Answer: C
NEW QUESTION # 30
What is the primary purpose of the telecommunications bonding infrastructure?
- A. Provide backup power to the telecommunications equipment when primary power to the equipment fails.
- B. Improve the performance of the installed telecommunications equipment
- C. Equalize potentials between metallic surfaces and equipment within entrance facilities
Answer: C
NEW QUESTION # 31
Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?
- A. Telephone test set
- B. TDR
- C. Qualification tester
- D. Wire map tester
Answer: D
NEW QUESTION # 32
......
BICSI IN101_V7 Certification Exam assesses the knowledge and skills of professionals in various areas, including copper and fiber optic cabling installation, testing, and troubleshooting. IN101_V7 exam covers topics such as ANSI/TIA/EIA and ISO/IEC industry standards, safety guidelines, and best practices for installation, testing, and maintenance. Additionally, the exam evaluates the candidate's knowledge of the different types of cables, connectors, and tools used in the installation process. Passing the BICSI IN101_V7 Certification Exam demonstrates an individual's proficiency in low voltage cabling infrastructure installation and maintenance, making them a valuable asset to any organization that relies on ICT systems.